نتایج جستجو برای: motion correction

تعداد نتایج: 374011  

Journal: :archives of cardiovascular imaging 0
bernhard bischoff institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany; institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany. tel: +49-89440044858 lucas l geyer institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany maximilian f reiser institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany ullrich g mueller lisse institute for clinical radiology, ludwig-maximilians-university hospital munich, 80337 munchen, germany; dzhk (german centre for cardiovascular research), partner site munich heart alliance, munich, germany

background motion artifacts that degrade image quality of coronary ct angiography (ccta) in patients with high heart rates may be reduced with specific automatic motion correction algorithms (amc). conclusions ccta image quality improves significantly with amc in patients with high heart rates and reduces the proportion of non-diagnostic examinations. results mean heart rate during ccta was 61 ...

رجبی, حسین, شیرازی, علیرضا , صادقی, مهدی, محمدی, ایرج, پولادیان, مجید ,

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

Arman Rahmim

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

Journal: :iranian journal of nuclear medicine 2005
arman rahmim

with the arrival of increasingly higher resolution pet systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. in this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. for the first type of motion...

Journal: :asia oceania journal of nuclear medicine and biology 0
michael masoomi 1-department of nuclear medicine, farwaniya hospital, kuwait anne h mclean 2-nuclear medicine physics, queen alexandra hospital, portsmouth, uk yassine bouchareb 3-clinical physics, barts health, nhs trust, uk. will ryder 4-faculty of health science, university of sydney, sydney, australia andy robinson 5-the harley street clinic, london, uk

abstractobjective: to investigate the impact of respiratory motion on localization, and quantification lung lesions for the gross tumour volume utilizing an in-house developed auto3dreg programme and dynamic nurbs-based cardiac-torso digitised phantom (ncat). methods: respiratory motion may result in more than 30% underestimation of the suv values of lung, liver and kidney tumour lesions. the m...

Journal: :iranian journal of nuclear medicine 2007
kourosh ebrahim nejad gorgi hossein rajabi ebrahim hajizadeh faraz kalantari hadi taleshi

introduction: there are several technical features that make pet an ideal device for the noninvasive evaluation of cardiac physiology. organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac pet imaging. these motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent lesion size and shape and reduci...

Ebrahim Hajizadeh Faraz Kalantari, Hadi Taleshi Hossein Rajabi, Kourosh Ebrahim Nejad Gorgi

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

Ahmad Bitarafan rajabi, Khadijeh Bamneshin Parham Geramifar Seied Mohsen Shahabi Seied Rabi Mahdavi,

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

Andy Robinson Anne McLean Michael Masoomi, Will Ryder Yassine Bouchareb,

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

پایان نامه :دانشگاه آزاد اسلامی - دانشگاه آزاد اسلامی واحد تهران مرکزی - دانشکده هنر و معماری 1393

" استاپ موشن" (stop motion) یا انیمیشن ایست – حرکتی یکی از تکنیک های ساخت انیمیشن که در آن با استفاده از فیلمبرداری فریم به فریم اشیاء فیزیکی را به حرکت در می آورند و از پشت سر هم قراردادن تصاویر این حرکت های فریم به فریم، تصور حرکت القا می شود. "موشن گرافیک" (motion graphic) نیز یکی دیگر از تکنیک های ساخت انیمیشن است. این تکنیک با استفاده از تکنولوژی ویدئو و با ایجاد توهم حرکت یا تغییر در ظاهر...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید